Commercial RO Membrane Elements
Commercial RO elements designed for packaged water treatment systems.
Continuous Reliability
For hotels, restaurants, hospitals and packaged RO plants, these elements offer model-specific flow and rejection ratings under the stated test conditions. Confirm suitability for the feed water and duty cycle.
Institutions
Stable Reject
Tap Water for Commercial Applications
Scroll horizontally to view all specifications.
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), pH 7 (± 0.5), 15% recovery, at the test pressure shown for each model
- Active Area m² (ft²)
- 1.2 (13)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 1203 (318)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 3.3 (36)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 1987 (525)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 2.7 (29)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 2869 (758)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 4.7 (50)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 3407 (900)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.5 (80)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow LPD (GPD)
- 8706 (2300)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5), 15% recovery
Yellow tape wrapped
Brackish Water for Commercial Applications
Scroll horizontally to view all specifications.
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), pH 7 (± 0.5), 15% recovery, at the test pressure shown for each model
- Active Area m² (ft²)
- 1.2 (13)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 1203 (318)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 3.3 (36)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 1987 (525)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 2.7 (29)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 2869 (758)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 4.7 (50)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 3407 (900)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.5 (80)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow LPD (GPD)
- 9085 (2400)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.5 (80)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow LPD (GPD)
- 9464 (2500)
- Stabilized Salt Rejection (%)
- 99.7%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.5 (80)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow LPD (GPD)
- 9085 (2400)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.5 (80)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow LPD (GPD)
- 9085 (2400)
- Stabilized Salt Rejection (%)
- 98.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500–2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5), 15% recovery
Energy Saving
Scroll horizontally to view all specifications.
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.7 (82)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 9842 (2600)
- Stabilized Salt Rejection (%)
- 99.5%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.9 (85)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 10977 (2900)
- Stabilized Salt Rejection (%)
- 99.7%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.5 (80)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 9464 (2500)
- Stabilized Salt Rejection (%)
- 99.3%
- Recovery %
- 15
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
CW Series — Car Wash & Spot-Free Rinse
Scroll horizontally to view all specifications.
Test conditions: flow and rejection at 500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 3.99 (43)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 5110 (1350)
- Stabilized Salt Rejection (%)
- 99.2%
- Recovery %
- 15
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 7.9 (85)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 10978 (2900)
- Stabilized Salt Rejection (%)
- 99.2%
- Recovery %
- 15
- Feed Spacer mil
- 31
Test conditions: flow and rejection at 500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 8.8 (95)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 12113 (3200)
- Stabilized Salt Rejection (%)
- 99.2%
- Recovery %
- 15
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 9.8 (105)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 13627 (3600)
- Stabilized Salt Rejection (%)
- 99.2%
- Recovery %
- 15
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 33.9 (365)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 37854 (10000)
- Stabilized Salt Rejection (%)
- 99.2%
- Recovery %
- 15
- Feed Spacer mil
- 34
Test conditions: flow and rejection at 500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 43532 (11500)
- Stabilized Salt Rejection (%)
- 99.2%
- Recovery %
- 15
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
- Active Area m² (ft²)
- 40.9 (440)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow LPD (GPD)
- 49210 (13000)
- Stabilized Salt Rejection (%)
- 99.2%
- Recovery %
- 15
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5), 15% recovery
4021 and 4040 elements: 4″ × 21″ and 4″ × 40″; 365, 400 and 440 elements: 8″ × 40″