Industrial RO Membrane Elements
Industrial RO elements for power, pharmaceutical, food and beverage, and manufacturing applications.
Industrial performance
Listed industrial elements are tested at 6.9 or 10.3 bar (100 or 150 psi), with model-specific flow and rejection figures below. Selection is subject to feed-water qualification.
Brackish Water for Industrial Applications
Scroll horizontally to view all specifications.
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 34.0 (365)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 35.96 (9500)
- Stabilized Salt Rejection %
- 99.5%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 34.0 (365)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 35.96 (9500)
- Stabilized Salt Rejection %
- 99.5%
- Feed Spacer mil
- 34
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 39.74 (10500)
- Stabilized Salt Rejection %
- 99.5%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 39.74 (10500)
- Stabilized Salt Rejection %
- 99.5%
- Feed Spacer mil
- 34
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 41.0 (440)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 43.53 (11500)
- Stabilized Salt Rejection %
- 99.5%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 39.74 (10500)
- Stabilized Salt Rejection %
- 99.5%
- Feed Spacer mil
- 34
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 43.53 (11500)
- Stabilized Salt Rejection %
- 98.5%
- Feed Spacer mil
- 34
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
High Performance / Fouling Resistant
Scroll horizontally to view all specifications.
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 43.53 (11500)
- Stabilized Salt Rejection %
- 99.7%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 43.53 (11500)
- Stabilized Salt Rejection %
- 99.7%
- Feed Spacer mil
- 34
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 43.53 (11500)
- Stabilized Salt Rejection %
- 99.7%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 43.53 (11500)
- Stabilized Salt Rejection %
- 99.7%
- Feed Spacer mil
- 34
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 41.0 (440)
- Test pressure bar (psi)
- 10.3 (150)
- Permeate Flow m³/d (GPD)
- 47.88 (12650)
- Stabilized Salt Rejection %
- 99.7%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 2,000 ppm NaCl, 25 °C (77 °F), 10.3 bar (150 psi), pH 7 (± 0.5)
Low Energy
Scroll horizontally to view all specifications.
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow m³/d (GPD)
- 43.53 (11500)
- Stabilized Salt Rejection %
- 99.5%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 41.0 (440)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow m³/d (GPD)
- 49.21 (13000)
- Stabilized Salt Rejection %
- 99.5%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow m³/d (GPD)
- 49.21 (13000)
- Stabilized Salt Rejection %
- 99.7%
- Feed Spacer mil
- 28
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5)
- Active Area m² (ft²)
- 37.2 (400)
- Test pressure bar (psi)
- 6.9 (100)
- Permeate Flow m³/d (GPD)
- 45.42 (12000)
- Stabilized Salt Rejection %
- 99.3%
- Feed Spacer mil
- 34
Test conditions: flow and rejection at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5)