Skip to main content
Industrial RO element

BW-28-400-LE

BW-28-400-LE is a low-energy-family spiral-wound thin-film composite RO element. Elements in this range undergo vacuum integrity testing and carry serial numbers.

Element size
203.2 × 1,016 mm
Salt rejection
99.5%
Permeate flow
43.532 m³/d (11,500 GPD)

Tested at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5).

Request a quote

Lead time is confirmed with your quote and depends on order size.

Model
BW-28-400-LE
Segment
Industrial
Family
Low-Energy
Element size
8" × 40"
Active area
37.2 m² (400 ft²)
Feed spacer
28 mil
Salt rejection
99.5%
Permeate flow
43.532 m³/d (11,500 GPD)
Test pressure
6.9 bar (100 psi)
Max temperature
45°C
Maximum operating pressure
On request
pH range (operation / cleaning)
On request
TDS class
brackish

Tested at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5).

Other sizes in this family

Cross-referenced models

Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.

Application review required unless badged otherwise.

View certificates by facility and product scope.

Frequently asked questions

What is the salt rejection of BW-28-400-LE?

BW-28-400-LE is listed at 99.5% salt rejection. Tested at 1,500 ppm NaCl, 25 °C (77 °F), 6.9 bar (100 psi), pH 7 (± 0.5).

What element size is BW-28-400-LE?

BW-28-400-LE is a 8" × 40" spiral-wound RO element (size code 8040). Listed maximum operating temperature is 45°C.

Which models is BW-28-400-LE cross-referenced with?

BW-28-400-LE is cross-referenced with AXEON XE1-8040 (Comparable specifications), DuPont (FilmTec) LE-400 (Comparable specifications), DuPont (FilmTec) XFRLE-400 (Comparable specifications), DuPont (FilmTec) BW30LE-440 (Comparable specifications), Toray TML20-400 (Application review required), Toray TML20-400D (Application review required) and others. Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.

Request a quote