Skip to main content
Seawater RO element

SW-28-2540-HRLE

SW-28-2540-HRLE is a seawater-family spiral-wound thin-film composite RO element. Elements in this range undergo vacuum integrity testing and carry serial numbers.

Element size
63.5 × 1,016 mm
Salt rejection
99.6%
Permeate flow
2.574 m³/d (680 GPD)

Tested at 32,000 ppm NaCl, 25 °C (77 °F), 55.2 bar (800 psi), pH 7 (± 1.0), 8% recovery.

Request a quote

Lead time is confirmed with your quote and depends on order size.

Model
SW-28-2540-HRLE
Segment
Seawater
Element size
2.5" × 40"
Active area
2.6 m² (28 ft²)
Feed spacer
28 mil
Salt rejection
99.6%
Permeate flow
2.574 m³/d (680 GPD)
Test pressure
55.2 bar (800 psi)
Max temperature
45°C
Maximum operating pressure
On request
pH range (operation / cleaning)
On request

Tested at 32,000 ppm NaCl, 25 °C (77 °F), 55.2 bar (800 psi), pH 7 (± 1.0), 8% recovery.

Cross-referenced models

Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.

Application review required unless badged otherwise.

View certificates by facility and product scope.

Frequently asked questions

What is the salt rejection of SW-28-2540-HRLE?

SW-28-2540-HRLE is listed at 99.6% salt rejection. Tested at 32,000 ppm NaCl, 25 °C (77 °F), 55.2 bar (800 psi), pH 7 (± 1.0), 8% recovery.

What element size is SW-28-2540-HRLE?

SW-28-2540-HRLE is a 2.5" × 40" spiral-wound RO element (size code 2540). Listed maximum operating temperature is 45°C.

Which models is SW-28-2540-HRLE cross-referenced with?

SW-28-2540-HRLE is cross-referenced with Toray TBW-2540HR (Application review required), Hydranautics (Nitto) SWC4-2540 (Application review required), LG Chem (NanoH2O) LG SW 2540 R (Application review required), Koch (Separation Solutions) TFC-2540-SW (Application review required), Vontron SW21-2540 (Application review required), CSM (Toray Chemical Korea) RE2540-SH (Application review required). Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.