SW-28-400-HR
SW-28-400-HR is a seawater-family spiral-wound thin-film composite RO element, vacuum integrity tested and shipped with its own serial number and datasheet.
- Model
- SW-28-400-HR
- Segment
- Seawater
- Family
- Seawater
- Element size
- 8" × 40"
- Salt rejection
- 99.8%
- Permeate flow
- 6500 GPD
- Test pressure
- 800 psi
- Max temperature
- 45°C
Cross-referenced models
Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.
- DuPont (FilmTec) SW30-400Comparable specifications
- DuPont (FilmTec) SW30HRLE-400Application review required
- DuPont (FilmTec) SW30XLE-440Application review required
- DuPont (FilmTec) SW30HR-380Comparable specifications
- DuPont (FilmTec) SEAMAXX-440iApplication review required
- Toray TM820H-400Comparable specifications
- Toray TM820K-400Application review required
- Toray TM820V-400Comparable specifications
- Toray TM820V-440Application review required
- Toray TBW-400HRApplication review required
- Toray TBW-400XHRApplication review required
- Hydranautics (Nitto) SWC3+Application review required
- Hydranautics (Nitto) SWC4Comparable specifications
- Hydranautics (Nitto) SWC4+Comparable specifications
- Hydranautics (Nitto) SWC4 MAXApplication review required
- Hydranautics (Nitto) SWC5 MAXApplication review required
- Hydranautics (Nitto) SWC5 LDApplication review required
- Hydranautics (Nitto) SWC6 MAXApplication review required
- LG Chem (NanoH2O) LG SW 365 RApplication review required
- LG Chem (NanoH2O) LG SW 400 RApplication review required
- LG Chem (NanoH2O) LG SW 400 SRApplication review required
- LG Chem (NanoH2O) LG SW 400 SR G2Application review required
- LG Chem (NanoH2O) LG SW 400 ESApplication review required
- LG Chem (NanoH2O) LG SW 440 RApplication review required
- LG Chem (NanoH2O) LG SW 440 GR G2Application review required
- Koch (Separation Solutions) TFC-8040-SW-400Comparable specifications
- Koch (Separation Solutions) TFC-8040-HF-400Application review required
- Veolia (formerly SUEZ) SC8040FComparable specifications
- Veolia (formerly SUEZ) AC-400,34Application review required
- Veolia (formerly SUEZ) AD-400,34Application review required
- Lanxess (LewaBrane) LewaBrane S 400 HRComparable specifications
- Lanxess (LewaBrane) LewaBrane S 440 HRApplication review required
- Vontron SW22-8040Comparable specifications
- Vontron HSW-8040Application review required
- CSM (Toray Chemical Korea) RE8040-SHApplication review required
- CSM (Toray Chemical Korea) RE8040-SHF400Comparable specifications
- CSM (Toray Chemical Korea) RE8040-SHNApplication review required
Frequently asked questions
What is the salt rejection of SW-28-400-HR?
SW-28-400-HR is tested to 99.8% salt rejection at 800 psi test pressure.
What element size is SW-28-400-HR?
SW-28-400-HR is a 8" × 40" spiral-wound RO element (industry size code 8040), rated for a maximum operating temperature of 45°C.
Which membranes is SW-28-400-HR equivalent to?
SW-28-400-HR is cross-referenced with DuPont (FilmTec) SW30-400 (Comparable specifications), DuPont (FilmTec) SW30HRLE-400 (Application review required), DuPont (FilmTec) SW30XLE-440 (Application review required), DuPont (FilmTec) SW30HR-380 (Comparable specifications), DuPont (FilmTec) SEAMAXX-440i (Application review required), Toray TM820H-400 (Comparable specifications) and others. Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.