RE-1812-75 / ES-1812-75
RE-1812-75 / ES-1812-75 is a residential-family spiral-wound thin-film composite RO element. Elements in this range undergo vacuum integrity testing and carry serial numbers.
- Element size
- 45.72 × 304.8 mm
- Salt rejection
- 97%
- Permeate flow
- 0.284 m³/d (75 GPD)
Tested at 250 ppm NaCl, 25 °C (77 °F), 4.8 bar (70 psi), pH 7 (± 0.5), 15% recovery.
Lead time is confirmed with your quote and depends on order size.
- Model
- RE-1812-75 / ES-1812-75
- Segment
- Residential
- Element size
- 1.8" × 12"
- Salt rejection
- 97%
- Permeate flow
- 0.284 m³/d (75 GPD)
- Test pressure
- 4.8 bar (70 psi)
- Max temperature
- 45°C
- Maximum operating pressure
- On request
- pH range (operation / cleaning)
- On request
Tested at 250 ppm NaCl, 25 °C (77 °F), 4.8 bar (70 psi), pH 7 (± 0.5), 15% recovery.
Other sizes in this family
- RE-1812-35 / ES-1812-35
- RE-1812-50 / ES-1812-50
- RE-2012-80 / ES-2012-80
- RE-2012-100 / ES-2012-100
- RE-2012-150 / ES-2012-150
- RE-2012-200 / ES-2012-200
- RE-3012-300 / RE-3013-300 / ES-3012-300 / ES-3013-300
- RE-3012-400 / RE-3013-400 / ES-3012-400 / ES-3013-400
- RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500
- RE-3012-600 / RE-3013-600 / ES-3012-600 / ES-3013-600
Cross-referenced models
Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.
Application review required unless badged otherwise.
- DuPont (FilmTec) TW30-1812-75
- DuPont (FilmTec) TW30-1812-100
- DuPont (FilmTec) TW30-1812-100HREngineering review required
- Toray TLC-75
- Toray TLC-100
- Hydranautics (Nitto) CPA-1812-75
- LG Chem (NanoH2O) LG RE 1812-75
- Veolia (formerly SUEZ) AG-1812-50
- Veolia (formerly SUEZ) AG-1812-75
- Lanxess (LewaBrane) LewaBrane B 1812-75
- Vontron ULP1812-50
- Vontron ULP1812-75
- Vontron HOR1812-75Engineering review required
- CSM (Toray Chemical Korea) RE1812-50
- CSM (Toray Chemical Korea) RE1812-75
- CSM (Toray Chemical Korea) RE1812-100
Frequently asked questions
What is the salt rejection of RE-1812-75 / ES-1812-75?
RE-1812-75 / ES-1812-75 is listed at 97% salt rejection. Tested at 250 ppm NaCl, 25 °C (77 °F), 4.8 bar (70 psi), pH 7 (± 0.5), 15% recovery.
What element size is RE-1812-75 / ES-1812-75?
RE-1812-75 / ES-1812-75 is a 1.8" × 12" spiral-wound RO element (size code 1812). Listed maximum operating temperature is 45°C.
Which models is RE-1812-75 / ES-1812-75 cross-referenced with?
RE-1812-75 / ES-1812-75 is cross-referenced with DuPont (FilmTec) TW30-1812-75 (Application review required), DuPont (FilmTec) TW30-1812-100 (Application review required), DuPont (FilmTec) TW30-1812-100HR (Engineering review required), Toray TLC-75 (Application review required), Toray TLC-100 (Application review required), Hydranautics (Nitto) CPA-1812-75 (Application review required) and others. Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.