RE-1812-75 / ES-1812-75
RE-1812-75 / ES-1812-75 is a residential-family spiral-wound thin-film composite RO element, vacuum integrity tested and shipped with its own serial number and datasheet.
- Model
- RE-1812-75 / ES-1812-75
- Segment
- Residential
- Family
- Residential
- Element size
- 1.8" × 12"
- Salt rejection
- 97%
- Permeate flow
- 75 GPD
- Test pressure
- 70 psi
- Max temperature
- 45°C
Cross-referenced models
Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.
- DuPont (FilmTec) TW30-1812-75Application review required
- DuPont (FilmTec) TW30-1812-100Application review required
- DuPont (FilmTec) TW30-1812-100HREngineering review required
- Toray TLC-75Application review required
- Toray TLC-100Application review required
- Hydranautics (Nitto) CPA-1812-75Application review required
- LG Chem (NanoH2O) LG RE 1812-75Application review required
- Veolia (formerly SUEZ) AG-1812-50Application review required
- Veolia (formerly SUEZ) AG-1812-75Application review required
- Lanxess (LewaBrane) LewaBrane B 1812-75Application review required
- Vontron ULP1812-50Application review required
- Vontron ULP1812-75Application review required
- Vontron HOR1812-75Engineering review required
- CSM (Toray Chemical Korea) RE1812-50Application review required
- CSM (Toray Chemical Korea) RE1812-75Application review required
- CSM (Toray Chemical Korea) RE1812-100Application review required
Frequently asked questions
What is the salt rejection of RE-1812-75 / ES-1812-75?
RE-1812-75 / ES-1812-75 is tested to 97% salt rejection at 70 psi test pressure.
What element size is RE-1812-75 / ES-1812-75?
RE-1812-75 / ES-1812-75 is a 1.8" × 12" spiral-wound RO element (industry size code 1812), rated for a maximum operating temperature of 45°C.
Which membranes is RE-1812-75 / ES-1812-75 equivalent to?
RE-1812-75 / ES-1812-75 is cross-referenced with DuPont (FilmTec) TW30-1812-75 (Application review required), DuPont (FilmTec) TW30-1812-100 (Application review required), DuPont (FilmTec) TW30-1812-100HR (Engineering review required), Toray TLC-75 (Application review required), Toray TLC-100 (Application review required), Hydranautics (Nitto) CPA-1812-75 (Application review required) and others. Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.