RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500 is a residential-family spiral-wound thin-film composite RO element. Elements in this range undergo vacuum integrity testing and carry serial numbers.

Element size
76.2 × 304.8 mm
Salt rejection
97%
Permeate flow
1.893 m³/d (500 GPD)

Tested at 250 ppm NaCl, 25 °C (77 °F), 5.2 bar (75 psi), pH 7 (± 0.5), 15% recovery.

Request a quote

Lead time is confirmed with your quote and depends on order size.

Model
RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500
Segment
Residential
Element size
3" × 12"
Salt rejection
97%
Permeate flow
1.893 m³/d (500 GPD)
Test pressure
5.2 bar (75 psi)
Max temperature
45°C
Maximum operating pressure
On request
pH range (operation / cleaning)
On request

Tested at 250 ppm NaCl, 25 °C (77 °F), 5.2 bar (75 psi), pH 7 (± 0.5), 15% recovery.

Other sizes in this family

Cross-referenced models

Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.

Application review required unless badged otherwise.

View certificates by facility and product scope.

Frequently asked questions

What is the salt rejection of RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500?

RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500 is listed at 97% salt rejection. Tested at 250 ppm NaCl, 25 °C (77 °F), 5.2 bar (75 psi), pH 7 (± 0.5), 15% recovery.

What element size is RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500?

RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500 is a 3" × 12" spiral-wound RO element (size code 3012). Listed maximum operating temperature is 45°C.

Which models is RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500 cross-referenced with?

RE-3012-500 / RE-3013-500 / ES-3012-500 / ES-3013-500 is cross-referenced with Toray TLC-500 (Engineering review required), Vontron ULP3013-500 (Engineering review required), CSM (Toray Chemical Korea) RE3013-500 (Engineering review required). Cross-references support initial selection. Confirm feed water, operating conditions and system compatibility with Hi-Tech before replacement. Published specifications may use different test conditions.